top of page
Alexis pump 9-10-2020 PNG.png

BATTERY CLAMPS

POWER INVERTER

VMAX 3.3

AMP CHARGER

 Alexis® 12 Volt Peristaltic Pump

C$ 1858.59

Item# ALXPERRI-20000

Quantity: 1

​

If you wish to to increase quantities, please do this after adding 1 unit to the shopping cart.

PRODUCT INFO
SPECIFICATIONS
PUMP CHART

Designed for the Field Technician in mind!

The Alexis® compact peristaltic pump can either run on its self-contained internal 30 amp AGM battery or plug it into a 120-volt electric socket. The Alexis® only weighs 37 pounds making this peristaltic pump lightweight and extremely durable. The rugged Pelican™ 1430 case enclosure is made of impact and corrosion-resistant ABS plastic to withstand demanding work conditions. Incorporating the most accurate and precise variable speed controller for consistent flow rates ensures the technician reliable sample integrity. The Alexis® peristaltic pump includes a built-in digital display and sealed push buttons to control several unique functions of this diversified peristaltic pump. And always remember ..... Sample Like A Champ! 
​
Constant Voltage Boosting Technology (CVBT)
Proprietary system that boosts a "low voltage battery" to an amazing range of 13.5 volts. That means faster water discharge rates and more consistent pumping rates. Which in turn makes your next groundwater field sampling event a profit center! 

​

Masterflex Easyload™ 2 pump head design

Superfast tubing load times; No more stretching and jamming silicon tubing through the pump head

and defiantly no more fiddling with screws to gain access to the pump head. Located on the side of

the rugged Pelican case exterior allowing the user to easily shut the enclosure.

​

Long-Lasting Internal AGM Battery with Precise Push Button Technology
An amazing 30 Amp AGM rechargeable long-life internal battery! The benefits of a 30 Amp AGM battery means you get extra long sampling runs. How does up to 12 hours of continuous sampling running at a full 100%! Now you will get the job done faster by eliminating the need to carry an external battery for your small peristaltic pumps and always fearing that you may run the battery out during long sampling events (or even worse off forgetting the battery at the office). With the convenient internal battery charger indicator, you will know exactly how much battery power is left with a simple push of a button! Have a power supply? With the AC or 12v DC adapters, you can set up and run your Alexis® peristaltic pump indefinitely.
 
Super strong - Lightweight Pelican™ 1430 case
The Alexis® small peristaltic pump utilizes a Pelican™ 1430 case that lends hand to hand durability and weighs only 37 pounds. The rugged Pelican™ case enclosure is made of impact and corrosion-resistant ABS plastic to withstand demanding work conditions.
 
Tell Me More LCD Display
Tells you real-time flow control. That means you will visually see your

current setting on the LCD screen when retrieving a sample.
 
Push Button Back Flushing
Supplied with a push-button reversible flow feature for back-flushing.
​
Low Voltage Disconnect Warning (LVD)
Simply put, the LVD is a "battery saver device". If the internal battery should ever fall below 10.75 volts into the critical "red" level of the "Internal Battery Charger Indicator" area then the Alexis® will turn off..... In short, the LVD telling you that the internal battery needs a charge. This advanced technology will prolong the life of the internal battery


Protection From Reverse Polarity
If you should reverse polarity the battery clamps when hooking up the Alexis® peristaltic pump to an external battery, the built-in internal protection engages not allowing the Alexis pump to turn on.

alexis top view of LCD panel i need  www
alexis-pump head.png
athena

BATTERY CLAMPS

BATTERY NOT INCLUDED

10' DUAL MALE

CIGARETTE PLUG

athena - PNG (clear background)2.png

Athena® 12 Volt Peristaltic Pump

C$ 1567.97

Item# ATHPERI-10000

Quantity: 1

​

If you wish to to increase quantities, please do this after adding 1 unit to the shopping cart.

PRODUCT INFO
SPECIFICATIONS
PUMP CHART

Designed for the Field Technician in mind!

The Athena® peristaltic pump is lightweight and compact. To use, simply attach an external power source such as a 12-volt deep cycle battery to energize the pump. A high-performance motor consumes only 3 amps at maximum draw making Athena® peristaltic pump extremely efficient. The rugged Pelican™ 1300 case enclosure is made of impact and corrosion-resistant ABS plastic to withstand demanding work conditions. Incorporating the most accurate and precise variable speed controller for consistent flow rates will ensure the technician reliable and consistent sample integrity. Includes a built-in digital display and sealed push buttons that are used to control the Athena® peristaltic pump.
 
Constant Voltage Boosting Technology (CVBT)
Proprietary system that boosts a "low voltage battery" to an amazing range of 13.5-14.5 volts when pressing the up and down button. That means faster water discharge rates and more consistent pumping rates. Which in turn makes your next groundwater field sampling event a profit center! 

​

Masterflex Easyload™ 2 pump head design

Superfast tubing load times; No more stretching and jamming silicon tubing through the pump head

and defiantly no more fiddling with screws to gain access to the pump head. Located on case exterior 

allowing the user to easily shut the enclosure.

​

Precise Push Button Technology

Hook up clamps to an external battery.
​
Super strong - Lightweight Pelican™ 1300 case
The Athena® peristaltic pump utilizes a Pelican™ 1300 case that lends hand to durability and weighs only 8 pounds. The rugged Pelican™ case enclosure is made of impact and corrosion-resistant ABS plastic to withstand demanding work conditions.
​
Tell Me More LCD Display
Athena® LCD tells you real-time flow control. That means you will visually see your current

setting on the LCD screen when retrieving a sample using the Athena® peristaltic pump.
 
Push Button Back Flushing
Supplied with a push-button reversible flow feature for back-flushing.

​

Low Voltage Disconnect Warning (LVD)
The Athena® has a low voltage disconnect at 11 volts. 
In short, the Athena® will shut off

automatically if the battery output voltage drops to 10.75 volts or lower. In short, the battery

is reaching a “critical low level” so stop using the unit immediately and please recharge your

battery within 24 hours.

 

Internal Fuse Replacement

If the Internal Fuse “blows”, it will automatically shut off the pump. This only happens if you should accidentally “reverse polarity” the pump clamps to the battery. The Internal Fuse will need to be replaced with another 20-amp blade fuse. The fuse is simple to replace. Please open panel to replace the fuse it is located on the bottom of the computer board. Unplug the power plug from the battery. Simply unscrew the screws from the panel, then replace fuse. Now, hook up the power plug to the battery terminals again. Turn on the power and the pump is ready to use.

alexis-pump head.png
Athena Pump PNG display CLOSEUP FINAL 8-
athena-dc input.png
electra

BATTERY CLAMPS

BATTERY NOT INCLUDED

10' DUAL MALE

CIGARETTE PLUG

electra - PNG (clear background).png

Electra® 12 Volt Peristaltic Pump

C$ 1297.63

Item# ELEPERRI-30000

Quantity: 1

​

If you wish to to increase quantities, please do this after adding 1 unit to the shopping cart.

PRODUCT INFO
SPECIFICATIONS
PUMP CHART

Designed for the Field Technician in mind!

 

The Electra® peristaltic pump is lightweight and compact. To use, simply attach an external power source such as a 12-volt deep cycle battery to energize the pump. A high-performance motor consumes only 3 amps at maximum draw making Electra® peristaltic pump extremely efficient. The rugged Pelican™ 1300 case enclosure is made of impact and corrosion-resistant ABS plastic to withstand demanding work conditions. Incorporating the most accurate and precise variable speed controller for consistent flow rates will ensure the technician reliable and consistent sample integrity.

 

Constant Voltage Boosting Technology (CVBT)

Proprietary system that boosts a "low voltage battery" to an amazing range of 13.5-14.5 volts when the dial is turned up 100%. That means faster water discharge rates and more consistent pumping rates. Which in turn makes your next groundwater field sampling event a profit center! 

 

Push Button Back Flushing

Supplied with a push-button reversible flow feature for back-flushing.

 

Precise Flow Technology:

Obtain precise sampling by utilizing simple dial-in technology using the rheostat on the side of

the Electra® pump. Turn up the dial for faster pumping or turn down the dial to achieve the

perfect low flow sample as low as 40 mls per minute, in conjunction with the low flow control valve.

​

Masterflex Easyload™ 2 pump head design

Super fast tubing load times; No more stretching and jamming silicon tubing through the

pump head and defiantly no more fiddling with screws to gain access to the pump head.

Located on case exterior allowing the user to easily shut the enclosure.

​

Super strong - Lightweight Pelican™ 1300 case

The Electra® peristaltic pump utilizes a Pelican™ 1300 case that lends hand to durability and weighs only 8 pounds. The rugged Pelican™ case enclosure is made of impact and corrosion-resistant ABS plastic to withstand demanding work conditions.

 

Low Voltage Disconnect Warning (LVD)

If the LVD (Low Voltage Disconnect) light appears red (located next to the low flow control dial), the pump will shut off automatically which indicates the battery output voltage is 10.75 volts or lower.  In short, the battery is reaching a “critical low level” so stop using the unit immediately and please recharge your battery within 24 hours.

 

Fuse Replacement

Two fuses are located inside the 3.05 meters (10-foot) cigarette DC male power plug cord, please makes sure you check these two fuses before checking the internal fuse. Please replace with another 30 AMP glass fuse if blown. 

If the Internal Fuse “blows”, it will automatically shut off the pump. This only happens if you should accidentally “reverse polarity” the pump clamps to the battery. In addition, incorporated into the mother board is an internal 7.5 AMP fuse. The fuse is simple to replace. Please open panel to replace the 7.5 AMP fuse. It is located on the master board. Simply unplug the 3.05 meters (10-foot) power plug from the battery and then cut the cable ties that lock the case closed. Once gaining access to the fuse compartment you can now replace fuse with a new 7.5 AMP fuse. Now, hook up the power plug to the battery terminals again. Turn on the power and the pump is ready to use.

electra-controls.png
alexis-pump head.png

Push Button Back

Low Flow

Control Dial

flatrateshippinglarge1.png
bottom of page